CLASS I ONGOING Drug recall · Reported 7 Feb 2024 · FDA Enforcement Report

VANCOmycin HCl PF added to 0.9% Sodium Chloride IV recalled

Denver Solutions is recalling VANCOmycin HCl PF added to 0.9% Sodium Chloride IV, distributed nationwide in the US. The recall was initiated on 28 Dec 2023 and the FDA has classified it as Class I.

Check your package

Lot, batch or date codesLot #: 2331184, Exp. Date 02/13/2024; 2331185, Exp. Date 02/10/2024; 2331189, Exp. Date 02/20/2024; 2331191, Exp. Date 02/24/2024; 2331258,Exp. Date 03/03/2024; 2331317, Exp. Date 03/15/2024.
Quantity recalled10,152 IV bags

Check the lot number on your package against the affected lots. If it matches, contact the pharmacy that dispensed it or your prescriber before stopping any medication.

Recall details

Recall number
D-0281-2024
FDA event ID
93710
Recalling firm
Denver Solutions, Englewood, CO
Classification
Class I
Status
Ongoing
Recall initiated
28 Dec 2023
FDA classified
29 Jan 2024
Reported
7 Feb 2024
Type
Voluntary: Firm initiated
Customers notified by
E-Mail
Reason category
Potency & Assay
Drug class
Antibiotics

Timeline

28 Dec 2023Recall initiated by company
29 Jan 2024Classified by FDA+32 days
7 Feb 2024Published in enforcement report+9 days

Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.

Reason for recall

Superpotent Drug: semi-automated IV bag filling system can malfunction and provide a double dose of drug product to IV bags.

Potency and specification recalls happen when a batch tests outside its approved limits for strength, purity or dissolution, which can mean the dose delivered is higher or lower than labelled.

Product as listed by the FDA

VANCOmycin HCl PF 1.25g added to 0.9% Sodium Chloride 250 mL IV bag, Item F3206, for IV use only; Leiters 13796 Compark Blvd Englewood, CO 80112; NDC 71449-028-68.

Where it was distributed

Nationwide within the United States

Nationwide

Questions about this recall

Why was it recalled?

Superpotent Drug: semi-automated IV bag filling system can malfunction and provide a double dose of drug product to IV bags.

Which lots are affected?

Lot #: 2331184, Exp. Date 02/13/2024; 2331185, Exp. Date 02/10/2024; 2331189, Exp. Date 02/20/2024; 2331191, Exp. Date 02/24/2024; 2331258,Exp. Date 03/03/2024; 2331317, Exp. Date 03/15/2024.

Where was it sold?

Nationwide within the United States

What should I do if I have it?

Check the lot number on your package against the affected lots. If it matches, contact the pharmacy that dispensed it or your prescriber before stopping any medication.

What does Class I mean?

Class I is the most serious FDA recall category: there is a reasonable probability that using the product will cause serious health consequences or death.

Read the official FDA notice · Source record retrieved 26 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.