CLASS II Device recall · Reported 28 Nov 2018 · FDA Enforcement Report

AIA-2000 Analyzer recalled by Tosoh Bioscience

Tosoh Bioscience is recalling AIA-2000 Analyzer, distributed nationwide in the US. The recall was initiated on 28 Sep 2018 and the FDA has classified it as Class II.

Check your package

Lot, batch or date codesSerial Nos. 10038409, 10038509, 10048009R, 10058011, 10069507, 80018112, 80039511
Quantity recalled7

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

Recall details

Recall number
Z-0475-2019
FDA event ID
81194
Recalling firm
Tosoh Bioscience, Grove City, OH
Classification
Class II
Status
Terminated
Recall initiated
28 Sep 2018
FDA classified
16 Nov 2018
Reported
28 Nov 2018
Type
Voluntary: Firm initiated
Customers notified by
Letter
Reason category
Potency & Assay

Timeline

28 Sep 2018Recall initiated by company
16 Nov 2018Classified by FDA+49 days
28 Nov 2018Published in enforcement report+12 days

Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.

Reason for recall

There is a possibility that the liquid suction pump on some AIA-2000 analyzers may not perform as intended and cause an insufficient volume of wash solution to be removed during the washing step. Incomplete washing of the sample may result in falsely elevated test results for the sandwich assays and falsely decreased test results for the competitive binding assays. Insufficient washing is detectable through review of the calibration data and QC trending. For example, if incomplete washing occurs, the reported values for the zero- calibration rate will be above the acceptance range. The calibration value may shift and the instrument will not calibrate successfully. If this issue occurs, there may be a delay in testing and reporting patient test results. There have been no user or patient injuries reported related to this issue.

Potency and specification recalls happen when a batch tests outside its approved limits for strength, purity or dissolution, which can mean the dose delivered is higher or lower than labelled.

Product as listed by the FDA

AIA-2000 Analyzer, Model Nos. AIA-2000LA, AIA-2000ST - Product Usage: The AIA-2000 is capable of performing three methods of immunoassay: an immunoenzymetric (IEMA) or sandwich immunoassay, a competitive binding (EIA) immunoassay, and a two-step immunoenzymetric immunoassay. An antigen-antibody reaction begins by combining a patient sample, control, or calibrator with a diluent in an immunoreaction test cup from the AIA-PACK reagent series.

Where it was distributed

US Nationwide distribution in the states of Florida, Kentucky, Maryland, Ohio, Pennsylvania, and Texas.

Nationwide FloridaKentuckyMarylandOhioPennsylvaniaTexas

Questions about this recall

Is AIA-2000 Analyzer recalled?

Yes. Tosoh Bioscience recalled AIA-2000 Analyzer on 28 Sep 2018. The recall is Class II and its status is Terminated. Recall number Z-0475-2019.

Why was it recalled?

There is a possibility that the liquid suction pump on some AIA-2000 analyzers may not perform as intended and cause an insufficient volume of wash solution to be removed during the washing step. Incomplete washing of the sample may result in falsely elevated test results for the sandwich assays and falsely decreased test results for the competitive binding assays. Insufficient washing is detectable through review of the calibration data and QC trending. For example, if incomplete washing occurs, the reported values for the zero- calibration rate will be above the acceptance range. The calibration value may shift and the instrument will not calibrate successfully. If this issue occurs, there may be a delay in testing and reporting patient test results. There have been no user or patient injuries reported related to this issue.

Which lots are affected?

Serial Nos. 10038409, 10038509, 10048009R, 10058011, 10069507, 80018112, 80039511

Where was it sold?

US Nationwide distribution in the states of Florida, Kentucky, Maryland, Ohio, Pennsylvania, and Texas.

What should I do if I have it?

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

What does Class II mean?

Class II means the product may cause temporary or medically reversible health problems, or the probability of serious harm is remote.

Read the official FDA notice · Source record retrieved 21 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.