CLASS II Device recall · Reported 22 Apr 2015 · FDA Enforcement Report

Master Drug Library recalled by Baxter Healthcare

Baxter Healthcare is recalling Master Drug Library, distributed in 21 states. The recall was initiated on 2 Mar 2015 and the FDA has classified it as Class II.

Check your package

Lot, batch or date codesSoftware version 8.0, Product Code 35723V080
Quantity recalled58 MDLs

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

Recall details

Recall number
Z-1451-2015
FDA event ID
70658
Recalling firm
Baxter Healthcare, Deerfield, IL
Classification
Class II
Status
Terminated
Recall initiated
2 Mar 2015
FDA classified
16 Apr 2015
Reported
22 Apr 2015
Type
Voluntary: Firm initiated
Customers notified by
Telephone
Reason category
Device Malfunction
Device type
Infusion Pumps

Timeline

2 Mar 2015Recall initiated by company
16 Apr 2015Classified by FDA+45 days
22 Apr 2015Published in enforcement report+6 days

Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.

Reason for recall

Loading/Bolus default dose settings in the Master Drug Library and the values shown on the pump during programming may differ. MDL drug dose time in seconds will round to the nearest integer in minutes on the pump dose setup screen (20 sec may show as 1 min on the pump display). The pump will administer drugs as configured. The discrepancy may cause therapy delay or unintended rate of delivery.

Device recalls are issued when a component, software or design fault could cause the device to fail or give wrong readings. Many are corrections applied in the field rather than physical returns.

Product as listed by the FDA

Master Drug Library Software version 8.0, Product Code 35723V080, to be used with SIGMA Spectrum Infusion System (Pump) version 8.0, Product Code 35700BAX2 The SIGMA Spectrum Infusion Pump with Master Drug Library (MDL) is intended to be used for the controlled administration of fluids.

Where it was distributed

Worldwide Distribution: US Distribution to states of: CA, CT, FL, IA, IL, IN, LA, MA, MD, MI, MN, MO, NC, NE, NH, NY, SD, TX, UT, WV, including Puerto Rico and country of: Canada.

CaliforniaConnecticutFloridaIowaIllinoisIndianaLouisianaMassachusettsMarylandMichiganMinnesotaMissouriNorth CarolinaNebraskaNew HampshireNew YorkPuerto RicoSouth DakotaTexasUtah

Questions about this recall

Is Master Drug Library recalled?

Yes. Baxter Healthcare recalled Master Drug Library on 2 Mar 2015. The recall is Class II and its status is Terminated. Recall number Z-1451-2015.

Why was it recalled?

Loading/Bolus default dose settings in the Master Drug Library and the values shown on the pump during programming may differ. MDL drug dose time in seconds will round to the nearest integer in minutes on the pump dose setup screen (20 sec may show as 1 min on the pump display). The pump will administer drugs as configured. The discrepancy may cause therapy delay or unintended rate of delivery.

Which lots are affected?

Software version 8.0, Product Code 35723V080

Where was it sold?

Worldwide Distribution: US Distribution to states of: CA, CT, FL, IA, IL, IN, LA, MA, MD, MI, MN, MO, NC, NE, NH, NY, SD, TX, UT, WV, including Puerto Rico and country of: Canada.

What should I do if I have it?

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

What does Class II mean?

Class II means the product may cause temporary or medically reversible health problems, or the probability of serious harm is remote.

Read the official FDA notice · Source record retrieved 21 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.

More recalls from Baxter Healthcare

All 564

Other Infusion Pumps recalls

All 546