CLASS III Device recall · Reported 14 Feb 2018 · FDA Enforcement Report
Medtronic Ascenda(R) Intrathecal Catheter recalled
Medtronic Neuromodulation is recalling Medtronic Ascenda(R) Intrathecal Catheter, distributed nationwide in the US. The recall was initiated on 21 Sep 2017 and the FDA has classified it as Class III.
Check your package
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
Recall details
- Recall number
- Z-0537-2018
- FDA event ID
- 78406
- Recalling firm
- Medtronic Neuromodulation, Minneapolis, MN
- Classification
- Class III
- Status
- Terminated
- Recall initiated
- 21 Sep 2017
- FDA classified
- 23 Feb 2018
- Reported
- 14 Feb 2018
- Type
- Voluntary: Firm initiated
- Customers notified by
- Letter
- Reason category
- Other Reasons
- Device type
- Heart & Vascular Devices
Timeline
| 21 Sep 2017 | Recall initiated by company | |
| 14 Feb 2018 | Published in enforcement report | +146 days |
| 23 Feb 2018 | Classified by FDA | +9 days |
Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.
Reason for recall
There is a possibility that specific lots of catheters that have recently been distributed may be at risk for an increased potential for kinking at the proximal end where the catheter connects to the drug infusion pump.
Product as listed by the FDA
Medtronic Ascenda(R) Intrathecal Catheter, Models: (a) 8780, UDI: 00643169202122, 00643169783027 (b) 8781, UDI: 00643169202139 (c) 8784, UDI: 00643169202153 The Ascenda Intrathecal Catheter kits (models 8780, 8781 and 8784) contain parts of an infusion system that delivers drugs to the intrathecal space. The implanted system consists of an implantable infusion pump and an Ascenda catheter. The catheter connects to the pump at the catheter port and enters the intrathecal space.
Where it was distributed
Nationwide Distribution
Questions about this recall
Why was it recalled?
There is a possibility that specific lots of catheters that have recently been distributed may be at risk for an increased potential for kinking at the proximal end where the catheter connects to the drug infusion pump.
Which lots are affected?
(a) Model 8780: N740471001, N740482002, N740507001, N741669001, N741918005, N742124002, N742180002, N742214002, N743749002, N747547001, N740471002, N740482003, N740507002, N741669002, N742077001, N742124004, N742180003, N742214003, N743749004, N747547003, N740471003, N740482004, N740507003, N741669003, N742077002, N742124005, N742180004, N742214004, N743749005, N747547004, N740471004, N740482005, N740507004, N741669004, N742077003, N742124006, N742180006, N742214005, N743749006, N747547005, N740471005, N740482006, N740507005, N741669005, N742077004, N742143001, N742184003, N742942001, N743773001, N740471006, N740496001, N740507006, N741669006, N742077005, N742143002, N742184004, N742942002, N743773002, N740476001, N740496003, N740508001, N741677001, N742077006, N742143005, N742184005, N742942003, N743773003, N740476002, N740496004, N740508002, N741677002, N742088001, N742143006, N742184006, N742942004, N743773004, N740476004, N740496005, N740508003, N741677004, N742088002, N742151001, N742197001, N742942005, N743773005, N740476006, N740496006, N740508004, N741677006, N742088003, N742158002, N742197002, N742977001, N743800006, N740477001, N740500001, N740508006, N741688001, N742088004, N742158003, N742197003, N742977002, N744024001, N740477002, N740500003, N740511001, N741688002, N742088005, N742158004, N742197004, N742977003, N744024002, N740477003, N740500004, N740511002, N741688003, N742088006, N742158005, N742197005, N742977004, N744024003, N740477004, N740500005, N740511003, N741688004, N742093002, N742158006, N742197006, N742977005, N744024004, N740477005, N740500006, N740511004, N741688005, N742093004, N742172001, N742211001, N743157002, N744024005, N740477006, N740506001, N740511005, N741688006, N742093005, N742172002, N742211002, N743157003, N744024006, N740479003, N740506002, N740540002, N741918001, N742112003, N742172003, N742211003, N743157004, N747546001, N740479004, N740506003, N740540003, N741918002, N742112004, N742172004, N742211004, N743157005, N747546003, N740479005, N740506004, N740540005, N741918003, N742112006, N742172005, N742211005, N743157006, N747546004, N740482001, N740506006, N740540006, N741918004, N742124001, N742180001, N742214001, N743749001, N747546005 (b) Model 8781: N745579001, N745579002, N745579005, N745579006, N746858001 (c) Model 8784: N745557001, N745557002, N745557003, N745557004, N745557005
Where was it sold?
Nationwide Distribution
What should I do if I have it?
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
What does Class III mean?
Class III recalls are for products unlikely to cause any adverse health consequence, usually labelling or quality issues.
Read the official FDA notice · Source record retrieved 26 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.
More recalls from Medtronic Neuromodulation
All 86| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | Medtronic Pocket Adaptor Kit for Deep Brain Stimulation recalled | Medtronic Neuromodulation | Other | Nationwide |
| Device | CLASS II | Medtronic Pocket Adaptor Kit for Deep Brain Stimulation recalled | Medtronic Neuromodulation | Other | Nationwide |
| Device | CLASS II | A71200 Vanta" Clinician Programmer Application (CP App) recalled | Medtronic Neuromodulation | Device Malfunction | Nationwide |
| Device | CLASS II | Restore Clinician Programmer Application (CP App) recalled | Medtronic Neuromodulation | Device Malfunction | Nationwide |
| Device | CLASS II | Enhanced Verify Evaluation Handset (CFN HH90130FA) recalled | Medtronic Neuromodulation | Device Malfunction | Nationwide |
Other Heart & Vascular Devices recalls
All 6,199| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | Getinge PVC Thoracic Catheter, Soft PVC Right Angle recalled | Atrium Medical | Potency & Assay | Nationwide |
| Device | CLASS II | Products that contain the Pericare Wipes: *Bardex¿ I.C recalled | C.R. Bard | Other | Nationwide |
| Device | CLASS II | Products that contain the Pericare Wipes recalled by C.R. Bard | C.R. Bard | Other | Nationwide |
| Device | CLASS II | Products that contain the Pericare Wipes recalled by C.R. Bard | C.R. Bard | Other | Nationwide |
| Device | CLASS II | Getinge PVC Thoracic Catheter, Firm PVC Straight recalled | Atrium Medical | Potency & Assay | Nationwide |