CLASS II Device recall · Reported 25 Sep 2013 · FDA Enforcement Report

ProTime Microcoagulation System recalled by Assuramed

Assuramed is recalling ProTime Microcoagulation System, distributed nationwide in the US. The recall was initiated on 16 Jul 2013 and the FDA has classified it as Class II.

Check your package

Lot, batch or date codes*** 1) Product Number: PRO3-25; Lots: All Lots; Independence Medical Catalog Number: 55L2101002; *** 2) Product Number: PRO5-25; Lots: All Lots; Independence Medical Catalog Number: ICPRO525
Quantity recalled1) 72 units; 2) 56 units

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

Recall details

Recall number
Z-2198-2013
FDA event ID
65980
Recalling firm
Assuramed, Twinsburg, OH
Classification
Class II
Status
Terminated
Recall initiated
16 Jul 2013
FDA classified
13 Sep 2013
Reported
25 Sep 2013
Type
Voluntary: Firm initiated
Customers notified by
Letter
Reason category
Potency & Assay

Timeline

16 Jul 2013Recall initiated by company
13 Sep 2013Classified by FDA+59 days
25 Sep 2013Published in enforcement report+12 days

Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.

Reason for recall

The products may have been stored at temperatures outside their required storage conditions.

Potency and specification recalls happen when a batch tests outside its approved limits for strength, purity or dissolution, which can mean the dose delivered is higher or lower than labelled.

Product as listed by the FDA

ProTime Microcoagulation System; PROTIME CUVETTE AND PROTIME3 CUVETTE; Store the foil-pouched cuvettes refrigerated 2-8C (36 - 36F); MATERIALS PROVIDED; ProTime cuvettes with Tenderlett Plus; or; Protime3 cuvettes with Tenderlett Plus LV; Product Instructions; Antiseptic, gauze (with self-test package only); International Technidyne Corporation; 8 Olsen Avenue; Edison, NJ 08820 USA; a subsidiary of Thoratec Corporation The ProTime Microcoagulation System consists of a portable, battery operated instrument and disposable cuvette for quantitative determination of prothrombin time (PT) from fingerstick whole blood or anticoagulant-free venous whole blood. There are two different types of cuvettes available for use with the ProTime Microcoagulation System: a ProTime cuvette and a ProTime3 cuvette. The ProTime cuvette is black color coded and utilizes three channels for the PT assays and two channels for integral controls. It requires approximately 65 ul of blood (approximately 3 drops). The ProTime3 cuvette is blue color coded and utilizes one channel for PT assay and two channels for integral controls. The ProTime3 cuvette requires approximately 27 ul of blood (approximately 1 large drop). The ProTime Microcoagulation System is intended for professional use in the management of patients treated with oral anticoagulants or for patient self-testing.

Where it was distributed

Nationwide Distribution including AR, AZ, CA, CO, FL, IL, KY, LA, MI, NJ, NY, OH,OK, OR, SC, TX, UT, and WA.

Nationwide ArkansasArizonaCaliforniaColoradoFloridaIllinoisKentuckyLouisianaMichiganNew JerseyNew YorkOhioOklahomaOregonSouth CarolinaTexasUtahWashington

Questions about this recall

Is ProTime Microcoagulation System recalled?

Yes. Assuramed recalled ProTime Microcoagulation System on 16 Jul 2013. The recall is Class II and its status is Terminated. Recall number Z-2198-2013.

Why was it recalled?

The products may have been stored at temperatures outside their required storage conditions.

Which lots are affected?

*** 1) Product Number: PRO3-25; Lots: All Lots; Independence Medical Catalog Number: 55L2101002; *** 2) Product Number: PRO5-25; Lots: All Lots; Independence Medical Catalog Number: ICPRO525

Where was it sold?

Nationwide Distribution including AR, AZ, CA, CO, FL, IL, KY, LA, MI, NJ, NY, OH,OK, OR, SC, TX, UT, and WA.

What should I do if I have it?

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

What does Class II mean?

Class II means the product may cause temporary or medically reversible health problems, or the probability of serious harm is remote.

Read the official FDA notice · Source record retrieved 21 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.

More recalls from Assuramed

All 3
ReportedClassRecallCompanyReasonWhere
DeviceCLASS IIHemoccult II Sensa elite recalled by AssuramedAssuramedE. coliNationwide
DeviceCLASS IIDiaScreen Liquid Urine Controls: Positive recalled by AssuramedAssuramedPotency & AssayNationwide

Other Test Kits & Diagnostics recalls

All 2,656