CLASS II Device recall · Reported 28 Nov 2018 · FDA Enforcement Report
Tosoh AIA-900 immunoassay Analyzer recalled by Tosoh Bioscience
Tosoh Bioscience is recalling Tosoh AIA-900 immunoassay Analyzer, distributed in Georgia, New York. The recall was initiated on 28 Sep 2018 and the FDA has classified it as Class II.
Check your package
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
Recall details
- Recall number
- Z-0485-2019
- FDA event ID
- 81219
- Recalling firm
- Tosoh Bioscience, Grove City, OH
- Classification
- Class II
- Status
- Terminated
- Recall initiated
- 28 Sep 2018
- FDA classified
- 19 Nov 2018
- Reported
- 28 Nov 2018
- Type
- Voluntary: Firm initiated
- Customers notified by
- Letter
- Reason category
- Device Malfunction
- Device type
- Test Kits & Diagnostics
Timeline
| 28 Sep 2018 | Recall initiated by company | |
| 19 Nov 2018 | Classified by FDA | +52 days |
| 28 Nov 2018 | Published in enforcement report | +9 days |
Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.
Reason for recall
A software issue may cause the liquid volume detection entries for 2nd and 3rd reagent bottles to be overwritten with the data from the 1st reagent bottle. Tosoh has released software version 2.51 (or later) to fix the problem. This failure is mitigated by the hardware design. The consequence would be a slight delay in testing patient sample or reporting patient result.
Device recalls are issued when a component, software or design fault could cause the device to fail or give wrong readings. Many are corrections applied in the field rather than physical returns.
Product as listed by the FDA
Tosoh AIA-900 immunoassay Analyzer
Where it was distributed
Distributed to accounts in GA and NY.
Questions about this recall
Why was it recalled?
A software issue may cause the liquid volume detection entries for 2nd and 3rd reagent bottles to be overwritten with the data from the 1st reagent bottle. Tosoh has released software version 2.51 (or later) to fix the problem. This failure is mitigated by the hardware design. The consequence would be a slight delay in testing patient sample or reporting patient result.
Which lots are affected?
10313605 10503612 10634103
Where was it sold?
Distributed to accounts in GA and NY.
What should I do if I have it?
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
What does Class II mean?
Class II means the product may cause temporary or medically reversible health problems, or the probability of serious harm is remote.
Read the official FDA notice · Source record retrieved 26 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.
More recalls from Tosoh Bioscience
All 74| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | ST Aia-Pack Testosterone, IN Vitro Diagnostic Use Only recalled | Tosoh Bioscience | Potency & Assay | Nationwide |
| Device | CLASS II | Thyroglobulin Antibody (TgAB) Calibrator recalled by Tosoh Bioscience | Tosoh Bioscience | Potency & Assay | Nationwide |
| Device | CLASS II | Aia- Pack Hcg Calibrator Set-In Vitro Diagnostic for Bhcg recalled | Tosoh Bioscience | Potency & Assay | Nationwide |
| Device | CLASS II | Aia-pack Bhcg Calibration Verification Test Set-In Vitro recalled | Tosoh Bioscience | Potency & Assay | Nationwide |
| Device | CLASS II | AIA-900 Analyzer recalled by Tosoh Bioscience | Tosoh Bioscience | Potency & Assay | Nationwide |
Other Test Kits & Diagnostics recalls
All 2,671| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | Techno-Path Multichem AE Unassayed Level recalled | Techno-path Manufacturing | Potency & Assay | Nationwide |
| Device | CLASS II | Techno-Path Multichem AE Unassayed Level recalled | Techno-path Manufacturing | Potency & Assay | Nationwide |
| Device | CLASS II | Techno-Path Multichem AE Unassayed Level recalled | Techno-path Manufacturing | Potency & Assay | Nationwide |
| Device | CLASS II | MAS Omni Immune PRO Liquid Assayed Integrated Immunoassay recalled | Microgenics | Potency & Assay | Nationwide |
| Device | CLASS II | The ABL90 Flex and ABL90 Flex Plus analyzers are intended recalled | Radiometer Medical ApS | Labeling Errors | Nationwide |