CLASS I ONGOING Device recall · Reported 26 Jun 2024 · FDA Enforcement Report

Ventilator Hamilton-C6, PN recalled by Hamilton Medical AG

Hamilton Medical is recalling Ventilator Hamilton-C6, PN: 160021, distributed nationwide in the US. The recall was initiated on 15 May 2024 and the FDA has classified it as Class I.

Check your package

Lot, batch or date codesUDI: 07630002808590, Software Versions: SW v1.1.4, SW v1.1.5, SW v1.1.6
Quantity recalled68

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

Recall details

Recall number
Z-2020-2024
FDA event ID
94671
Recalling firm
Hamilton Medical, Bonaduz, N/A
Classification
Class I
Status
Ongoing
Recall initiated
15 May 2024
FDA classified
18 Jun 2024
Reported
26 Jun 2024
Type
Voluntary: Firm initiated
Customers notified by
Letter
Reason category
Device Malfunction

Timeline

15 May 2024Recall initiated by company
18 Jun 2024Classified by FDA+34 days
26 Jun 2024Published in enforcement report+8 days

Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.

Reason for recall

Ventilator may enter sensor fail mode, ventilation may not re-initiate, after patient is reconnected, which may cause hypoxia, if this sequence occurs: 1)User presses O2 enrichment, 2)User disconnects endotracheal tube for open suctioning, 3)Sensor error initiated, sensor fail mode occurs, 4)Patient is re-connected with sensor fail mode active, 5) Ventilation is not re-initiated by the ventilator.

Device recalls are issued when a component, software or design fault could cause the device to fail or give wrong readings. Many are corrections applied in the field rather than physical returns.

Product as listed by the FDA

Ventilator HAMILTON-C6, PN: 160021

Where it was distributed

US Nationwide distribution in the states of GA, KY, FL, IN, NV, MI, VA, OR, TX, SC, CA, PA.

Nationwide CaliforniaFloridaGeorgiaIndianaKentuckyMichiganNevadaOregonPennsylvaniaSouth CarolinaTexasVirginia

Questions about this recall

Why was it recalled?

Ventilator may enter sensor fail mode, ventilation may not re-initiate, after patient is reconnected, which may cause hypoxia, if this sequence occurs: 1)User presses O2 enrichment, 2)User disconnects endotracheal tube for open suctioning, 3)Sensor error initiated, sensor fail mode occurs, 4)Patient is re-connected with sensor fail mode active, 5) Ventilation is not re-initiated by the ventilator.

Which lots are affected?

UDI: 07630002808590, Software Versions: SW v1.1.4, SW v1.1.5, SW v1.1.6

Where was it sold?

US Nationwide distribution in the states of GA, KY, FL, IN, NV, MI, VA, OR, TX, SC, CA, PA.

What should I do if I have it?

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

What does Class I mean?

Class I is the most serious FDA recall category: there is a reasonable probability that using the product will cause serious health consequences or death.

Read the official FDA notice · Source record retrieved 26 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.

More recalls from Hamilton Medical

All 34

Other CPAP & Ventilators recalls

All 568