CLASS II Device recall · Reported 4 Sep 2019 · FDA Enforcement Report

Alinity ci -series System Control¿Module recalled

Abbott Gmbh & Co. KG is recalling Alinity ci -series System Control¿Module, distributed nationwide in the US. The recall was initiated on 10 Jun 2019 and the FDA has classified it as Class II.

Check your package

Lot, batch or date codesAll serial numbers
Quantity recalled1763 units

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

Recall details

Recall number
Z-2363-2019
FDA event ID
83235
Recalling firm
Abbott Gmbh & Co. KG, Wiesbaden, N/A
Classification
Class II
Status
Terminated
Recall initiated
10 Jun 2019
FDA classified
23 Aug 2019
Reported
4 Sep 2019
Type
Voluntary: Firm initiated
Customers notified by
Letter
Reason category
Device Malfunction

Timeline

10 Jun 2019Recall initiated by company
23 Aug 2019Classified by FDA+74 days
4 Sep 2019Published in enforcement report+12 days

Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.

Reason for recall

Abbott has identified an issue with all on market versions (v2.6.0 and v2.6.1) of Alinity ci series Software where incorrect results may occur after a system Stop due to the Alinity i re use of reaction vessels (RVs). This issue only occurs if the system is transitioned from Processing to Stopped to Idle.

Device recalls are issued when a component, software or design fault could cause the device to fail or give wrong readings. Many are corrections applied in the field rather than physical returns.

Product as listed by the FDA

Alinity ci -series System Control¿Module, Part Number 03R70 01 Product Usage: The Alinity ci series System Control Module has a scalable design to provide full integration of clinical chemistry and immunoassay analysis. The Alinity ci series System Control Module includes a clinical chemistry module and an immunoassay module, each performing all sample processing activities, and a system control module to provide a single user friendly interface. Each system can be customized by combining one or more sample processing modules, in multiple configurations, with a system control module to form a single workstation. The Alinity i Processing Module is a fully automated immunoassay analyzer allowing random and continuous access, as well as priority and automated retest processing using chemiluminescent microparticle immunoassay (CMIA) technology. CMIA technology is used to determine the presence of antigens, antibodies, and analytes in samples.

Where it was distributed

Worldwide Distribution - US Nationwide

Nationwide

Questions about this recall

Why was it recalled?

Abbott has identified an issue with all on market versions (v2.6.0 and v2.6.1) of Alinity ci series Software where incorrect results may occur after a system Stop due to the Alinity i re use of reaction vessels (RVs). This issue only occurs if the system is transitioned from Processing to Stopped to Idle.

Which lots are affected?

All serial numbers

Where was it sold?

Worldwide Distribution - US Nationwide

What should I do if I have it?

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

What does Class II mean?

Class II means the product may cause temporary or medically reversible health problems, or the probability of serious harm is remote.

Read the official FDA notice · Source record retrieved 26 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.

More recalls from Abbott Gmbh & Co. KG

All 19

Other Test Kits & Diagnostics recalls

All 2,668