CLASS II ONGOING Device recall · Reported 1 Feb 2023 · FDA Enforcement Report
Alinity m System recalled by Abbott Molecular
Abbott Molecular is recalling Alinity m System. The recall was initiated on 9 Dec 2022 and the FDA has classified it as Class II.
Check your package
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
Recall details
- Recall number
- Z-1009-2023
- FDA event ID
- 91286
- Recalling firm
- Abbott Molecular, Des Plaines, IL
- Classification
- Class II
- Status
- Ongoing
- Recall initiated
- 9 Dec 2022
- FDA classified
- 20 Jan 2023
- Reported
- 1 Feb 2023
- Type
- Voluntary: Firm initiated
- Customers notified by
- Letter
- Reason category
- Other Reasons
- Device type
- Other Medical Devices
Timeline
| 9 Dec 2022 | Recall initiated by company | |
| 20 Jan 2023 | Classified by FDA | +42 days |
| 1 Feb 2023 | Published in enforcement report | +12 days |
Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.
Reason for recall
The firm identified the following three potential issues which may have impacted ADUs installed on distributed Alinity m Systems. 1. Systems which had their ADUs serviced may have an incorrect board value (calibration data file) referenced causing a misconfiguration of the calibration. 2. Inability of Maintenance and Diagnostics 2300 (Amp Detect Optical Calibrations) to recognize error handling and thermal hold errors during the calibration process, potentially leading to a misconfiguration of the calibration. 3. Under specific conditions during the ADU manufacturing process, an incorrect calibration may potentially have been configured.
Product as listed by the FDA
Alinity m System. The Alinity m System is designed to automate the steps for nucleic acid testing, which includes sample processing, amplification, detection, and data reduction.
Where it was distributed
x
Questions about this recall
Why was it recalled?
The firm identified the following three potential issues which may have impacted ADUs installed on distributed Alinity m Systems. 1. Systems which had their ADUs serviced may have an incorrect board value (calibration data file) referenced causing a misconfiguration of the calibration. 2. Inability of Maintenance and Diagnostics 2300 (Amp Detect Optical Calibrations) to recognize error handling and thermal hold errors during the calibration process, potentially leading to a misconfiguration of the calibration. 3. Under specific conditions during the ADU manufacturing process, an incorrect calibration may potentially have been configured.
Which lots are affected?
Model Number: 08N53-002
Where was it sold?
x
What should I do if I have it?
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
What does Class II mean?
Class II means the product may cause temporary or medically reversible health problems, or the probability of serious harm is remote.
Read the official FDA notice · Source record retrieved 26 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.
More recalls from Abbott Molecular
All 36| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | Alinity m Resp-4-Plex Amplification (AMP) Kit (CE) recalled | Abbott Molecular | Other | Nationwide |
| Device | CLASS II | Alinity m Resp-4-Plex AMP Kit, List Number 09N79 recalled | Abbott Molecular | Other | Nationwide |
| Device | CLASS II | The Alinity m System is designed to automate the steps recalled | Abbott Molecular | Other | Nationwide |
| Device | CLASS II | Abbott Alinity m STI AMP Kit, used with the Alinity m System recalled | Abbott Molecular | Potency & Assay | Nationwide |
| Device | CLASS II | Abbott Alinity m HPV AMP Kit, used with the Alinity m System recalled | Abbott Molecular | Potency & Assay | Nationwide |
Other Other Medical Devices recalls
All 13,908| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | Plastics Tray kits recalled by Avid Medical | Avid Medical | Foreign Material | Nationwide |
| Device | CLASS II | Heart Prep Tray kits recalled by Avid Medical | Avid Medical | Other | Nationwide |
| Device | CLASS II | Pack Open Heart Cfh kits recalled by Avid Medical | Avid Medical | Other | Nationwide |
| Device | CLASS II | Sperm Ab Elisa (96 well plate test) recalled by DRG International | DRG International | Other | Nationwide |
| Device | CLASS III | BeneView Series recalled by Mindray DS USA | Mindray DS USA | Device Malfunction | Nationwide |