CLASS II Device recall · Reported 18 Feb 2015 · FDA Enforcement Report
GemLock Long Hex Driver recalled by Zimmer Dental
Zimmer Dental is recalling GemLock Long Hex Driver. The recall was initiated on 22 Jan 2015 and the FDA has classified it as Class II.
Check your package
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
Recall details
- Recall number
- Z-1115-2015
- FDA event ID
- 70304
- Recalling firm
- Zimmer Dental, Carlsbad, CA
- Classification
- Class II
- Status
- Terminated
- Recall initiated
- 22 Jan 2015
- FDA classified
- 12 Feb 2015
- Reported
- 18 Feb 2015
- Type
- Voluntary: Firm initiated
- Customers notified by
- Letter
- Reason category
- Device Malfunction
- Device type
- Surgical Instruments
Timeline
| 22 Jan 2015 | Recall initiated by company | |
| 12 Feb 2015 | Classified by FDA | +21 days |
| 18 Feb 2015 | Published in enforcement report | +6 days |
Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.
Reason for recall
The Gemlock Long Hex Driver may not fit into the Fixture Mount Transfer (FMT) or the internal hex of the implant.
Device recalls are issued when a component, software or design fault could cause the device to fail or give wrong readings. Many are corrections applied in the field rather than physical returns.
Product as listed by the FDA
GemLock Long Hex Driver, Catalog RHL2.5; Also distributed within the Tapered SwissPlus & SwissPlus Implant Systems Kits, Surgical, Complete, Catalog OPCST; Tapered Screw-Vent Implant System Surgical Kit, Complete, Catalog TSVKIT. Used as a manual delivery tool that engages the Fixture Mount Transfer (FMT) to transport the dental implant from the product packaging to the osteotomy.
Where it was distributed
Worldwide Distribution -- US, Argentina, Australia, Bulgaria, Canada, Chile, Colombia, Costa Rica, Dominican Republic, Ecuador, Egypt, France, Germany, Hong Kong, Hungary, Iran, Israel, Italy, Japan, Lebanon, Lithuania, Malaysia, Mexico, Morocco, Netherlands, Pakistan, Panama, Poland, Romania, Russia, Saudi Arabia, Serbia, Taiwan, Thailand, Tunisia, Turkey, and UAE. Expanded Distribution: Spain
Questions about this recall
Why was it recalled?
The Gemlock Long Hex Driver may not fit into the Fixture Mount Transfer (FMT) or the internal hex of the implant.
Which lots are affected?
Etched Lot No. 62699693 & 62735177. Lot Number on Label: 62712431, 62743168, 62766610, 62702589, 62710484, 62712437, 62743075, 62750487, 62753787, 62756920, 62759862, 62760388, 62768456, and 62773158. Expanded Lot No. 62728173.
Where was it sold?
Worldwide Distribution -- US, Argentina, Australia, Bulgaria, Canada, Chile, Colombia, Costa Rica, Dominican Republic, Ecuador, Egypt, France, Germany, Hong Kong, Hungary, Iran, Israel, Italy, Japan, Lebanon, Lithuania, Malaysia, Mexico, Morocco, Netherlands, Pakistan, Panama, Poland, Romania, Russia, Saudi Arabia, Serbia, Taiwan, Thailand, Tunisia, Turkey, and UAE. Expanded Distribution: Spain
What should I do if I have it?
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
What does Class II mean?
Class II means the product may cause temporary or medically reversible health problems, or the probability of serious harm is remote.
Read the official FDA notice · Source record retrieved 26 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.
More recalls from Zimmer Dental
All 33| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | Outer Package Label: Tapered Screw-Vent Implant System recalled | Zimmer Dental | Packaging Defects | Nationwide |
| Device | CLASS II | Tapered Screw-Vent MTX, Dental Implant, sterile recalled | Zimmer Dental | Labeling Errors | Nationwide |
| Device | CLASS II | Tapered Screw-Vent MTX, Dental Implant, sterile recalled | Zimmer Dental | Labeling Errors | Nationwide |
| Device | CLASS II | Instrument Kit System, Tapered Screw-Vent Implant System recalled | Zimmer Dental | Other | Nationwide |
| Device | CLASS II | Instrument Kit System, Tapered Screw-Vent Implant System recalled | Zimmer Dental | Other | Nationwide |
Other Surgical Instruments recalls
All 3,816| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | REF:2B5LT Ethicon Endo-Surgery recalled by Stryker Sustainability | Stryker Sustainability Solutions | Device Malfunction | Nationwide |
| Device | CLASS II | REF:B11LT Ethicon Endo-Surgery, Inc. Xcel Bladeless Trocar recalled | Stryker Sustainability Solutions | Device Malfunction | Nationwide |
| Device | CLASS II | REF:B12LT Ethicon Endo-Surgery, Inc. Xcel Bladeless Trocar recalled | Stryker Sustainability Solutions | Device Malfunction | Nationwide |
| Device | CLASS II | Hemospray Endoscopic Hemostat recalled by Wilson-Cook Medical | Wilson-Cook Medical | Device Malfunction | Nationwide |
| Device | CLASS II | REF:B5LT Ethicon Endo-Surgery recalled by Stryker Sustainability | Stryker Sustainability Solutions | Device Malfunction | Nationwide |