CLASS II Device recall · Reported 27 Aug 2014 · FDA Enforcement Report

IntelePACS software versions 3-8-1 to 4-9-1, Product Usage recalled

Intelerad Medical Systems is recalling IntelePACS software versions 3-8-1 to 4-9-1, Product Usage, distributed nationwide in the US. The recall was initiated on 3 Jul 2014 and the FDA has classified it as Class II.

Check your package

Lot, batch or date codessoftware versions 3-8-1 to 4-9-1
Quantity recalled230

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

Recall details

Recall number
Z-2267-2014
FDA event ID
68719
Recalling firm
Intelerad Medical Systems, Montreal
Classification
Class II
Status
Terminated
Recall initiated
3 Jul 2014
FDA classified
19 Aug 2014
Reported
27 Aug 2014
Type
Voluntary: Firm initiated
Customers notified by
Letter
Reason category
Device Malfunction

Timeline

3 Jul 2014Recall initiated by company
19 Aug 2014Classified by FDA+47 days
27 Aug 2014Published in enforcement report+8 days

Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.

Reason for recall

In specific situation a partially truncated file may be written to the IntelePACS server. This partially truncated file still can be viewed by InteleViewer and InteleViewer will report to the user that the file in question is complete. This situation only occurs if a file is partially truncated.

Device recalls are issued when a component, software or design fault could cause the device to fail or give wrong readings. Many are corrections applied in the field rather than physical returns.

Product as listed by the FDA

IntelePACS software versions 3-8-1 to 4-9-1, Product Usage: IntelePACS is a device that receives digital images and data from various sources (such as, CT scanners, MRI scanners, ultrasound systems, R/F units, computer and direct radiographic devices, secondary capture devices, scanners, imaging gateways, or other imaging sources.

Where it was distributed

Worldwide Distribution - USA Nationwide and the countries of Scotland, Ireland, United Kingdom, Canada, Australia, and New Zealand.

Nationwide

Questions about this recall

Why was it recalled?

In specific situation a partially truncated file may be written to the IntelePACS server. This partially truncated file still can be viewed by InteleViewer and InteleViewer will report to the user that the file in question is complete. This situation only occurs if a file is partially truncated.

Which lots are affected?

software versions 3-8-1 to 4-9-1

Where was it sold?

Worldwide Distribution - USA Nationwide and the countries of Scotland, Ireland, United Kingdom, Canada, Australia, and New Zealand.

What should I do if I have it?

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

What does Class II mean?

Class II means the product may cause temporary or medically reversible health problems, or the probability of serious harm is remote.

Read the official FDA notice · Source record retrieved 26 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.

More recalls from Intelerad Medical Systems

All 4

Other Imaging Equipment recalls

All 2,349