CLASS II ONGOING Device recall · Reported 20 May 2026 · FDA Enforcement Report
LVIS Intraluminal Support Device recalled by Microvention
Microvention is recalling LVIS Intraluminal Support Device. The recall was initiated on 6 Apr 2026 and the FDA has classified it as Class II.
Check your package
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
Recall details
- Recall number
- Z-2200-2026
- FDA event ID
- 98755
- Recalling firm
- Microvention, Aliso Viejo, CA
- Classification
- Class II
- Status
- Ongoing
- Recall initiated
- 6 Apr 2026
- FDA classified
- 14 May 2026
- Reported
- 20 May 2026
- Type
- Voluntary: Firm initiated
- Reason category
- Other Reasons
- Device type
- Other Medical Devices
Timeline
| 6 Apr 2026 | Recall initiated by company | |
| 14 May 2026 | Classified by FDA | +38 days |
| 20 May 2026 | Published in enforcement report | +6 days |
Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.
Reason for recall
Stent-assisted coiling device may due to commingling during manufacturing have dimensional nonconformance and/or incorrect device configuration. If device is oversized may lead to increased vessel wall stress, neointimal hyperplasia, vessel injury/rupture; if undersized may lead to incomplete expansion/malposition, acute stent thrombosis, distal embolization, ischemic neurological events
Product as listed by the FDA
LVIS Intraluminal Support Device, REF/Outside Diameter(OD)xTotal Length(TL)xWorking Length(WL): 214022-CAS/4.0 mm x 22 mm x 18 mm, 214518-CAS/4.5 mm x 18 mm x 14 mm, 213517-CAS/3.5 mm x 17 mm x 13 mm
Where it was distributed
International distribution to the country of China.
Questions about this recall
Why was it recalled?
Stent-assisted coiling device may due to commingling during manufacturing have dimensional nonconformance and/or incorrect device configuration. If device is oversized may lead to increased vessel wall stress, neointimal hyperplasia, vessel injury/rupture; if undersized may lead to incomplete expansion/malposition, acute stent thrombosis, distal embolization, ischemic neurological events
Which lots are affected?
Lots: 0000616462, 0000619851, 0000552987, 0000551725. UDI: (01)00842429115893(11)240325(17)270228(10)0000552987, (01)00842429115893(11)240325(17)270228(10)0000552987, (01)00842429115893(11)240325(17)270228(10)0000552987, (01)00842429115930(11)240325(17)270228(10)0000551725, (01)00842429115930(11)240325(17)270228(10)0000551725, (01)00842429115930(11)240610(17)270531(10)0000616462, (01)00842429115930(11)240610(17)270531(10)0000616462, (01)00842429115961(11)240610(17)270531(10)0000619851, (01)00842429115961(11)240610(17)270531(10)0000619851, (01)00842429115961(11)240610(17)270531(10)0000619851, (01)00842429115961(11)240610(17)270531(10)0000619851,
Where was it sold?
International distribution to the country of China.
What should I do if I have it?
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
What does Class II mean?
Class II means the product may cause temporary or medically reversible health problems, or the probability of serious harm is remote.
Read the official FDA notice · Source record retrieved 26 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.
More recalls from Microvention
All 38| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | Bobby Balloon Guide Catheter recalled by Microvention | Microvention | Device Malfunction | Nationwide |
| Device | CLASS II | Flow Re-Direction Endoluminal Devices: FRED recalled by Microvention | Microvention | Other | Nationwide |
| Device | CLASS II | Lifepearl Drug Elutable Microspheres: 200 +/- 50 micrometers recalled | Microvention | Other | GA |
| Device | CLASS II | MicoVention Terumo, LVIS Intraluminal Support Device recalled | Microvention | Other | CA |
| Device | CLASS II | Headway" 17 Advanced Straight Microcatheter with Hydrophilic Coating recalled | Microvention | Sterility | CA |
Other Other Medical Devices recalls
All 13,908| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | Plastics Tray kits recalled by Avid Medical | Avid Medical | Foreign Material | Nationwide |
| Device | CLASS II | Heart Prep Tray kits recalled by Avid Medical | Avid Medical | Other | Nationwide |
| Device | CLASS II | Pack Open Heart Cfh kits recalled by Avid Medical | Avid Medical | Other | Nationwide |
| Device | CLASS II | Sperm Ab Elisa (96 well plate test) recalled by DRG International | DRG International | Other | Nationwide |
| Device | CLASS III | BeneView Series recalled by Mindray DS USA | Mindray DS USA | Device Malfunction | Nationwide |