CLASS II ONGOING Device recall · Reported 18 Nov 2026 · FDA Enforcement Report

The product is a standard off the shelf syringe recalled by TransMedics

TransMedics is recalling The product is a standard off the shelf syringe, distributed nationwide in the US. The recall was initiated on 20 Nov 2025 and the FDA has classified it as Class II.

Check your package

Lot, batch or date codesOCS Liver Perfusion Set Serial Numbers from 4470-3-18076 to 4470-3-20343;
Quantity recalled1179 (Liver Perfusion Sets)

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

Recall details

Recall number
Z-0389-2027
FDA event ID
100092
Recalling firm
TransMedics, Andover, MA
Classification
Class II
Status
Ongoing
Recall initiated
20 Nov 2025
FDA classified
6 Nov 2026
Reported
18 Nov 2026
Reason category
Packaging Defects

Timeline

20 Nov 2025Recall initiated by company
6 Nov 2026Classified by FDA+351 days
18 Nov 2026Published in enforcement report+12 days

Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.

Reason for recall

Faulty Solution Delivery System (SDS) Cassettes within the device set were assembled with syringes that were manufactured with an atypical lubricant, which results in sub-par performance and has the potential to cause leaks.

Packaging recalls include wrong labels, wrong products in the wrong bottle, missing leaflets, short-filled or empty capsules and seals that fail.

Product as listed by the FDA

OCS Liver System for organ transport OCS Liver Perfusion Set Model/Catalog Number: 3200 Product Description: The recalled product is a standard off the shelf syringe. It is used as part of solution delivery cassette (SDS Cassette) to be used with the perfusion module of OCS Liver System. OCS Liver Perfusion Sets within the serial number range between 4470-3-18076 and 4470-3-20343 may contain SDS cassettes within the impacted lot range of 4459-6-737116 to 4459-6-739965. Each Liver Perfusion Set contains three SDS cassettes. The BD syringe is a component of SDS Cassette PN 100004459, which is an accessory of the Liver Perfusion Set.

Where it was distributed

Worldwide - US Nationwide distribution in the state of NE and the country of Italy.

NationwideNebraska

Questions about this recall

Why was it recalled?

Faulty Solution Delivery System (SDS) Cassettes within the device set were assembled with syringes that were manufactured with an atypical lubricant, which results in sub-par performance and has the potential to cause leaks.

Which lots are affected?

OCS Liver Perfusion Set Serial Numbers from 4470-3-18076 to 4470-3-20343;

Where was it sold?

Worldwide - US Nationwide distribution in the state of NE and the country of Italy.

What should I do if I have it?

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

What does Class II mean?

Class II means the product may cause temporary or medically reversible health problems, or the probability of serious harm is remote.

Read the official FDA notice · Source record retrieved 25 Nov 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.

Other products in this recall event

2 other products · FDA event 100092

This product is part of a recall event; the main page for the event is OCS Solution Delivery Cassettes The product is a standard recalled.

More recalls from TransMedics

All 10

Other Syringes & Needles recalls

All 1,071