CLASS II Device recall · Reported 3 Jun 2020 · FDA Enforcement Report
Skater Introducer Set 6F recalled by Argon Medical Devices
Argon Medical Devices is recalling Skater Introducer Set 6F. The recall was initiated on 26 Apr 2020 and the FDA has classified it as Class II.
Check your package
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
Recall details
- Recall number
- Z-2109-2020
- FDA event ID
- 85562
- Recalling firm
- Argon Medical Devices, Athens, TX
- Classification
- Class II
- Status
- Terminated
- Recall initiated
- 26 Apr 2020
- FDA classified
- 22 May 2020
- Reported
- 3 Jun 2020
- Type
- Voluntary: Firm initiated
- Customers notified by
- Reason category
- Other Reasons
- Device type
- Heart & Vascular Devices
Timeline
| 26 Apr 2020 | Recall initiated by company | |
| 22 May 2020 | Classified by FDA | +26 days |
| 3 Jun 2020 | Published in enforcement report | +12 days |
Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.
Reason for recall
Tungsten coils of the guidewire included in the introducer kit were detaching.
Product as listed by the FDA
Skater Introducer Set 6F x 18cm. REF/UDI: 651506300/(01)00886333005000; 655506300/(01)00886333005079 - Product Usage: The Skater Introducer System with radiopaque marker is intended for fine needle puncture and tissue dilation with subsequent positioning of a guidewire for catheter placement in non-vascular procedures.
Where it was distributed
International distribution to the countries of China, Taiwan.
Questions about this recall
Why was it recalled?
Tungsten coils of the guidewire included in the introducer kit were detaching.
Which lots are affected?
REF /LOT: 651506300/ 11267865, 11271397, 11277305, 11287825, 11293349, 11288772, 11290387, 11263199, 11262264, 11258778, 11254942, 11253443 REF/ LOT: 655506300 / 11268009, 11284776, 11266592, 11285976, 11287826, 11280359, 11260512, 11252843, 11248583, 11277295
Where was it sold?
International distribution to the countries of China, Taiwan.
What should I do if I have it?
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
What does Class II mean?
Class II means the product may cause temporary or medically reversible health problems, or the probability of serious harm is remote.
Read the official FDA notice · Source record retrieved 26 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.
More recalls from Argon Medical Devices
All 50| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | L-Cath PICC S/L Peripherally Inserted Central Catheter: (1.9F) recalled | Argon Medical Devices | Labeling Errors | 28 states |
| Device | CLASS II | L-Cath Midline S/L Catheter (3F) recalled by Argon Medical Devices | Argon Medical Devices | Labeling Errors | 28 states |
| Device | CLASS I | Bone Marrow Tray recalled by Argon Medical Devices | Argon Medical Devices | Sterility | Nationwide |
| Device | CLASS I | T-Lok Bone Marrow Tray recalled by Argon Medical Devices | Argon Medical Devices | Sterility | Nationwide |
| Device | CLASS I | One-Piece Introducer Tray recalled by Argon Medical Devices | Argon Medical Devices | Sterility | Nationwide |
Other Heart & Vascular Devices recalls
All 6,220| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | TufTex¿ Over-the-Wire Embolectomy Catheter recalled | LeMaitre Vascular | Other | Nationwide |
| Device | CLASS II | Endovascular Pack kits recalled by Avid Medical | Avid Medical | Other | Nationwide |
| Device | CLASS II | Bard Ep Xt Decapolar Steerable, Diagnostic Ep Catheter, 6f recalled | Stryker Sustainability Solutions | Particulate Matter | Nationwide |
| Device | CLASS II | Medical convenience kits containing BD CliniClean Pericare recalled | American Contract Systems | Device Malfunction | Nationwide |
| Device | CLASS II | Medical convenience kits containing BD CliniClean Pericare recalled | American Contract Systems | Device Malfunction | Nationwide |