CLASS II Device recall · Reported 28 Nov 2012 · FDA Enforcement Report
Specialty Audible Torque Wrench, Xia Is2217xlp recalled by Stryker Spine
Stryker Spine is recalling Specialty Audible Torque Wrench, Xia Is2217xlp, distributed nationwide in the US. The recall was initiated on 9 Aug 2012 and the FDA has classified it as Class II.
Check your package
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
Recall details
- Recall number
- Z-0382-2013
- FDA event ID
- 63386
- Recalling firm
- Stryker Spine, Allendale, NJ
- Classification
- Class II
- Status
- Terminated
- Recall initiated
- 9 Aug 2012
- FDA classified
- 19 Nov 2012
- Reported
- 28 Nov 2012
- Type
- Voluntary: Firm initiated
- Customers notified by
- Letter
- Reason category
- Other Reasons
- Device type
- Spinal Implants
Timeline
| 9 Aug 2012 | Recall initiated by company | |
| 19 Nov 2012 | Classified by FDA | +102 days |
| 28 Nov 2012 | Published in enforcement report | +9 days |
Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.
Reason for recall
Multiple complaints have reported the hex tip of the torque wrench fracturing during final tightening.
Product as listed by the FDA
SPECIALTY AUDIBLE TORQUE WRENCH, XIA IS2217XLP MFG BY: STRYKER SPINE 2 PEARL COURT ALLENDALE NJ 07401-1677 The Xia 3/Mantis Redux/Specialty Audible Torque Wrenches are used to final tighten the blocker of the Xia 3/ Mantis Redux Polyaxial Screws, Hooks, Monoaxial Screws, Rod to Rod Connectors and Off-set connectors. The Torque Wrench is a t-handle deflection beam torque wrench with a 5 mm hex tip. The instrument allows the controlled application of 12 Nm torque via a visual indicator on the bell shaped cylinder just below the handle. The Specialty Audible Torque Wrench has an extra feature where it creates and audible "click" when the desired final tightening torque is reached.
Where it was distributed
Worldwide Distribution - USA (nationwide) and internationally to Australia, Canada, France, Germany, Netherlands, Japan, Spain, Denmark, Switzerland, and the United Kingdom.
Questions about this recall
Why was it recalled?
Multiple complaints have reported the hex tip of the torque wrench fracturing during final tightening.
Which lots are affected?
Class I device, 510(K) exempt Catalog Number: IS2217XLP Lot Number: 2576, 2756
Where was it sold?
Worldwide Distribution - USA (nationwide) and internationally to Australia, Canada, France, Germany, Netherlands, Japan, Spain, Denmark, Switzerland, and the United Kingdom.
What should I do if I have it?
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
What does Class II mean?
Class II means the product may cause temporary or medically reversible health problems, or the probability of serious harm is remote.
Read the official FDA notice · Source record retrieved 26 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.
Other products in this recall event
2 other products · FDA event 63386| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| CLASS II | Stryker Mantis Torque Wrench recalled by Stryker Spine | Stryker Spine | Other | Nationwide | |
| CLASS II | Stryker Xia 3 Torque Wrench recalled by Stryker Spine | Stryker Spine | Other | Nationwide |
More recalls from Stryker Spine
All 29| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | Monterey AL Implant Inserter recalled by Stryker Spine | Stryker Spine | Other | 13 states |
| Device | CLASS II | Monterey AL Implant Inserter recalled by Stryker Spine | Stryker Spine | Other | 13 states |
| Device | CLASS II | Monterey AL Implant Inserter recalled by Stryker Spine | Stryker Spine | Other | 13 states |
| Device | CLASS II | Monterey AL Implant Inserter recalled by Stryker Spine | Stryker Spine | Other | 13 states |
| Device | CLASS II | AVS Anchor-C Cervical Cage System Instructions For Use recalled | Stryker Spine | Other | Nationwide |
Other Spinal Implants recalls
All 1,159| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | Extended Polyaxial Head, Attached Gimbal recalled | Seaspine Orthopedics | Other | Nationwide |
| Device | CLASS II | Medline Convenience Kits: Anterior Spine Pack recalled | Medline Industries | Other | Nationwide |
| Device | CLASS II | Neuro; Neuro; Crani; Ortho Spine Pack; Bmhm Neuro Pack recalled | Avid Medical | Sterility | Nationwide |
| Device | CLASS II | Halyard medical convenience kits labeled as: ENT recalled | Avid Medical | Sterility | Nationwide |
| Device | CLASS II | Halyard medical convenience kits labeled as: A-P PACK recalled | Avid Medical | Sterility | Nationwide |