CLASS II Device recall · Reported 1 Jun 2022 · FDA Enforcement Report

The VerifyNow P2Y12 Test is designed to measure platelet recalled

Accriva Diagnostics is recalling The VerifyNow P2Y12 Test is designed to measure platelet P2Y12 receptor blockade, distributed nationwide in the US. The recall was initiated on 30 Mar 2022 and the FDA has classified it as Class II.

Check your package

Lot, batch or date codesLot Number: WL1060, Expiration: 2023-03-01
Quantity recalled11

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

Recall details

Recall number
Z-1121-2022
FDA event ID
89936
Recalling firm
Accriva Diagnostics, San Diego, CA
Classification
Class II
Status
Terminated
Recall initiated
30 Mar 2022
FDA classified
20 May 2022
Reported
1 Jun 2022
Type
Voluntary: Firm initiated
Customers notified by
Letter
Reason category
Particulate Matter

Timeline

30 Mar 2022Recall initiated by company
20 May 2022Classified by FDA+51 days
1 Jun 2022Published in enforcement report+12 days

Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.

Reason for recall

Two whole blood Platelet Reactivity tests exist that share the same reagent formulation and are used to obtain P2Y12 Reactivity Unit results. The test without US-FDA market clearance was distributed and it displays BASE results not displayed by the US-FDA market cleared device. A formula is being provided to health care personnel to calculate the percentage of platelet aggregation inhibition.

Product as listed by the FDA

The VerifyNow P2Y12 Test is designed to measure platelet P2Y12 receptor blockade. Substances known to specifically block the P2Y12 receptor include ticagrelor and the thienopyridine class of drugs, including clopidogrel and prasugrel.1-8 The test is based upon the ability of activated platelets to bind fibrinogen. Fibrinogen-coated microparticles aggregate in whole blood in proportion to the number of expressed platelet GP IIb/IIIa receptors. Light transmittance increases as activated platelets bind and aggregate fibrinogen-coated beads. The instrument measures this change in optical signal and reports results in P2Y12 Reaction Units (PRU). The rate of microbead aggregation is more rapid and reproducible if platelets are activated; therefore, the reagent adenosine-5-diphosphate (ADP) is incorporated into the test channel to induce platelet activation. Prostaglandin E1 (PGE1) is included in the reagent mixture to increase the specificity of the PRU result to reflect P2Y12-mediated platelet aggregation. The reagents are formulated such to achieve reaction concentrations of 20 ¿M ADP and 22 nM PGE1. In a like manner, two other activators, iso-TRAP (Thrombin Receptor Activating Peptide) with PAR4-AP (PAR4-Activating Peptide) and fibrinogen-coated microparticles are incorporated into a second channel of the test device. The instrument measures the change in transmittance in this channel, calculates the baseline platelet function for the sample, and reports the percent inhibition result for the sample.

Where it was distributed

US Nationwide distribution in the state of California.

Nationwide California

Questions about this recall

Why was it recalled?

Two whole blood Platelet Reactivity tests exist that share the same reagent formulation and are used to obtain P2Y12 Reactivity Unit results. The test without US-FDA market clearance was distributed and it displays BASE results not displayed by the US-FDA market cleared device. A formula is being provided to health care personnel to calculate the percentage of platelet aggregation inhibition.

Which lots are affected?

Lot Number: WL1060, Expiration: 2023-03-01

Where was it sold?

US Nationwide distribution in the state of California.

What should I do if I have it?

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

What does Class II mean?

Class II means the product may cause temporary or medically reversible health problems, or the probability of serious harm is remote.

Read the official FDA notice · Source record retrieved 26 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.