CLASS II Device recall · Reported 3 Jul 2013 · FDA Enforcement Report

The Centricity Laboratory System is intended to be recalled

GE Healthcare It is recalling The Centricity Laboratory System is intended to be an information system designed to, distributed in Georgia, Minnesota, New York, Tennessee, Texas. The recall was initiated on 20 Nov 2012 and the FDA has classified it as Class II.

Check your package

Lot, batch or date codesSoftware Versions 3.3, 4.0, and 4.1
Quantity recalled9 Units

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

Recall details

Recall number
Z-1585-2013
FDA event ID
64789
Recalling firm
GE Healthcare It, Barrington, IL
Classification
Class II
Status
Terminated
Recall initiated
20 Nov 2012
FDA classified
24 Jun 2013
Reported
3 Jul 2013
Type
Voluntary: Firm initiated
Customers notified by
Letter
Reason category
Device Malfunction

Timeline

20 Nov 2012Recall initiated by company
24 Jun 2013Classified by FDA+216 days
3 Jul 2013Published in enforcement report+9 days

Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.

Reason for recall

If environment variables MICRO_CORRECT_MSG_TYPE and CORRECT_MSG_TYPE are set to different values, in Microbiology result entry when released results (Final Report released) are changed and the Corrected Result messages are edited on the free-text form, some of the originally entered panel free-text is lost. For this issue to occur the original result must be amended and the environmental variabl

Device recalls are issued when a component, software or design fault could cause the device to fail or give wrong readings. Many are corrections applied in the field rather than physical returns.

Product as listed by the FDA

The Centricity Laboratory System is intended to be an information system designed to support the clinical and administrative activities associated with the provision and utilization of clinical laboratory services and facilities, e.g., the storing and delivering of analytical results. It is a specially designed data program application (software), which is supplied for installation in existing mainframe or decentralized computers or a computer network. This software system will not be the software directly used to run, steer, or control any specific laboratory analyzer or equipment. It is intended for use in laboratory facilities, including a central laboratory or in a multiple laboratory environment servicing satellite laboratories, reference laboratories, clinics, etc. Centricity Laboratory System is not intended for direct patient contact.

Where it was distributed

Worldwide Distribution - US Distribution including the states of OH, NY, GA, TX, TN and MN and the countries of Australia, Qatar and England

GeorgiaMinnesotaNew YorkTennesseeTexas

Questions about this recall

Why was it recalled?

If environment variables MICRO_CORRECT_MSG_TYPE and CORRECT_MSG_TYPE are set to different values, in Microbiology result entry when released results (Final Report released) are changed and the Corrected Result messages are edited on the free-text form, some of the originally entered panel free-text is lost. For this issue to occur the original result must be amended and the environmental variabl

Which lots are affected?

Software Versions 3.3, 4.0, and 4.1

Where was it sold?

Worldwide Distribution - US Distribution including the states of OH, NY, GA, TX, TN and MN and the countries of Australia, Qatar and England

What should I do if I have it?

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

What does Class II mean?

Class II means the product may cause temporary or medically reversible health problems, or the probability of serious harm is remote.

Read the official FDA notice · Source record retrieved 26 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.