CLASS II Device recall · Reported 27 Jun 2018 · FDA Enforcement Report
Cryovalve(R) SG Pulmonary Human Heart Valve recalled by CryoLife
CryoLife is recalling Cryovalve(R) SG Pulmonary Human Heart Valve, distributed in Arkansas, Ohio. The recall was initiated on 14 May 2018 and the FDA has classified it as Class II.
Check your package
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
Recall details
- Recall number
- Z-2271-2018
- FDA event ID
- 80199
- Recalling firm
- CryoLife, Kennesaw, GA
- Classification
- Class II
- Status
- Terminated
- Recall initiated
- 14 May 2018
- FDA classified
- 21 Jun 2018
- Reported
- 27 Jun 2018
- Type
- Voluntary: Firm initiated
- Customers notified by
- Letter
- Reason category
- Other Reasons
- Device type
- Heart & Vascular Devices
Timeline
| 14 May 2018 | Recall initiated by company | |
| 21 Jun 2018 | Classified by FDA | +38 days |
| 27 Jun 2018 | Published in enforcement report | +6 days |
Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.
Reason for recall
Devices, which met FDA and AATB eligibility criteria, were distributed. Final autopsy and toxicology reports indicated the presence of morphine in the urine.
Product as listed by the FDA
Cryovalve(R) SG Pulmonary Human Heart Valve, Catalog Number SGPVVOO
Where it was distributed
AR, OH
Questions about this recall
Why was it recalled?
Devices, which met FDA and AATB eligibility criteria, were distributed. Final autopsy and toxicology reports indicated the presence of morphine in the urine.
Which lots are affected?
Serial Number 10988203
Where was it sold?
AR, OH
What should I do if I have it?
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
What does Class II mean?
Class II means the product may cause temporary or medically reversible health problems, or the probability of serious harm is remote.
Read the official FDA notice · Source record retrieved 26 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.
Other products in this recall event
1 other product · FDA event 80199| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| CLASS II | Cryopatch SG Pulmonary Human Cardiac Branch recalled by CryoLife | CryoLife | Other | AR, OH |
More recalls from CryoLife
All 14| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | BioGlue Surgical Adhesive recalled by CryoLife | CryoLife | Hidden Drug Ingredients | GA |
| Device | CLASS II | CryoPatch SG Pulmonary Human Cardiac Patch recalled by CryoLife | CryoLife | Device Malfunction | Nationwide |
| Device | CLASS II | CryoValve SG Pulmonary Human Heart Valve recalled by CryoLife | CryoLife | Device Malfunction | Nationwide |
| Device | CLASS II | CryoPatch SG Pulmonary Hemi-Artery Patch recalled by CryoLife | CryoLife | Other | TX |
| Device | CLASS II | On-X Aortic Heart Valve with Anatomic Sewing Ring recalled by CryoLife | CryoLife | Labeling Errors | Nationwide |
Other Heart & Vascular Devices recalls
All 6,268| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | Direxion Torqueable Microcatheter, Ngmc/Fathom/027/Straight/1RO/130 recalled | Boston Scientific Cork | Device Malfunction | Nationwide |
| Device | CLASS II | Direxion Torqueable Microcatheter, Ngmc/Single/021/Straight/1RO/130 recalled | Boston Scientific Cork | Device Malfunction | Nationwide |
| Device | CLASS II | Direxion Torqueable Microcatheter, Ngmc/Single/021/Straight/2RO/155 recalled | Boston Scientific Cork | Device Malfunction | Nationwide |
| Device | CLASS II | Direxion Torqueable Microcatheter, Ngmc/Single/021/Straight/2RO/130 recalled | Boston Scientific Cork | Device Malfunction | Nationwide |
| Device | CLASS II | Direxion Torqueable Microcatheter, Ngmc/Single/021/J/1RO/130 recalled | Boston Scientific Cork | Device Malfunction | Nationwide |