CLASS II Device recall · Reported 27 Jun 2012 · FDA Enforcement Report
The product is Pathfinder SL recalled by Spacelabs Healthcare
Spacelabs Healthcare is recalling The product is Pathfinder SL, distributed nationwide in the US. The recall was initiated on 11 May 2012 and the FDA has classified it as Class II.
Check your package
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
Recall details
- Recall number
- Z-1831-2012
- FDA event ID
- 61913
- Recalling firm
- Spacelabs Healthcare, Issaquah, WA
- Classification
- Class II
- Status
- Terminated
- Recall initiated
- 11 May 2012
- FDA classified
- 20 Jun 2012
- Reported
- 27 Jun 2012
- Type
- Voluntary: Firm initiated
- Customers notified by
- Letter
- Reason category
- Device Malfunction
- Device type
- Surgical Instruments
Timeline
| 11 May 2012 | Recall initiated by company | |
| 20 Jun 2012 | Classified by FDA | +40 days |
| 27 Jun 2012 | Published in enforcement report | +7 days |
Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.
Reason for recall
The firm received reports of the Pathfinder LS software crashing after editing a batch of Holter Analyzer records. The software will stop with an error message requiring a restart. In addition, QTc values will not update after moving the marker.
Device recalls are issued when a component, software or design fault could cause the device to fail or give wrong readings. Many are corrections applied in the field rather than physical returns.
Product as listed by the FDA
The product is Pathfinder SL, version 1.6.0.3057 software used with the Spacelabs Healthcare Pathfinder SL Holter Analyzer, version 1.6.0. Product Usage: The Holter Analyzer analyzes information collected from ambulatory electrocardiogram recorders worn by patients and used to assist physicians in diagnosis and patient monitoring. In addition, incorrect QTc values are reported after moving the cursor. QTc values are timing events between labeled points of interest in the ECG signal that the physician can mark with the cursor. The software is used to edit a family of events and upon conclusion the software crashes with an error message.
Where it was distributed
Worldwide Distribution - US (nationwide) including the states of Nevada and Vermont, and the countries of AUSTRALIA, AUSTRIA, CANADA, CYPRUS, GERMANY, ICELAND, ISRAEL, POLAND, ROMANIA, SOUTH AFRICA, SWITZERLAND, THAILAND, TURKEY and UNITED KINGDOM.
Questions about this recall
Why was it recalled?
The firm received reports of the Pathfinder LS software crashing after editing a batch of Holter Analyzer records. The software will stop with an error message requiring a restart. In addition, QTc values will not update after moving the marker.
Which lots are affected?
Version 1.6.0.
Where was it sold?
Worldwide Distribution - US (nationwide) including the states of Nevada and Vermont, and the countries of AUSTRALIA, AUSTRIA, CANADA, CYPRUS, GERMANY, ICELAND, ISRAEL, POLAND, ROMANIA, SOUTH AFRICA, SWITZERLAND, THAILAND, TURKEY and UNITED KINGDOM.
What should I do if I have it?
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
What does Class II mean?
Class II means the product may cause temporary or medically reversible health problems, or the probability of serious harm is remote.
Read the official FDA notice · Source record retrieved 26 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.
More recalls from Spacelabs Healthcare
All 47| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | Xhibit Central Station recalled by Spacelabs Healthcare | Spacelabs Healthcare | Device Malfunction | Nationwide |
| Device | CLASS II | Spacelabs Ultraview SL Command Module SL Command Module recalled | Spacelabs Healthcare | Packaging Defects | Nationwide |
| Device | CLASS II | Multi-parameter Command Module recalled by Spacelabs Healthcare | Spacelabs Healthcare | Labeling Errors | Nationwide |
| Device | CLASS II | Sentinel V11 recalled by Spacelabs Healthcare | Spacelabs Healthcare | Device Malfunction | Nationwide |
| Device | CLASS II | Branding is not applied to this product DVI display cables recalled | Spacelabs Healthcare | Device Malfunction | Nationwide |
Other Surgical Instruments recalls
All 3,809| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | Medline Convenience Kits: IV Start KIT recalled by Medline Industries | Medline Industries | Sterility | Nationwide |
| Device | CLASS II | Medline Convenience Kits containing BD ChloraPrep Clear recalled | Medline Industries | Packaging Defects | Nationwide |
| Device | CLASS II | Medline convenience kits labeled as: Open Heart Pack, Medline Kit recalled | Medline Industries | Other | Nationwide |
| Device | CLASS II | Medline convenience kits labeled as: GYN Robotic CDS, Medline Kit recalled | Medline Industries | Other | Nationwide |
| Device | CLASS II | Linvatec Genesys CrossFT Suture Anchor with Disposable Driver recalled | ConMed | Other | Nationwide |