CLASS I Device recall · Reported 30 Sep 2020 · FDA Enforcement Report
Profemur Neck Long Titanium recalled by MicroPort Orthopedics
MicroPort Orthopedics is recalling Profemur Neck Long Titanium. The recall was initiated on 31 Jul 2020 and the FDA has classified it as Class I.
Check your package
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
Recall details
- Recall number
- Z-2941-2020
- FDA event ID
- 86153
- Recalling firm
- MicroPort Orthopedics, Arlington, TN
- Classification
- Class I
- Status
- Terminated
- Recall initiated
- 31 Jul 2020
- FDA classified
- 18 Sep 2020
- Reported
- 30 Sep 2020
- Type
- Voluntary: Firm initiated
- Customers notified by
- Letter
- Reason category
- Other Reasons
- Device type
- Hip & Knee Implants
Timeline
| 31 Jul 2020 | Recall initiated by company | |
| 18 Sep 2020 | Classified by FDA | +49 days |
| 30 Sep 2020 | Published in enforcement report | +12 days |
Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.
Reason for recall
MicroPort Orthopedics Inc. states that there have been reports of fractures of the long and extra-long Titanium modular femoral neck component after implantation. Worldwide there were 680 Long and X-Long PROFEMUR Titanium modular neck fractures among 123,840 global sales representing is a cumulative rate of modular neck device fracture of 0.55% from 2002 to 2019. Within the United States there were 349 Long and X-Long PROFEMUR¿ Titanium modular neck fractures among 15,786 United States sales representing a cumulative rate of modular neck device fracture with a fracture rate in the United States of 2.21% from 2002 to 2019. There is an average time of 5.4 years to device fracture after implantation.
Product as listed by the FDA
PROFEMUR Neck Long Titanium, Catalog Numbers: PHA01204, PHA01214, PHA01224, PHA01234, PHA01244, PHA01254, PHA01264. Hip prosthesis component.
Where it was distributed
worldwide, except China and Japan
Questions about this recall
Why was it recalled?
MicroPort Orthopedics Inc. states that there have been reports of fractures of the long and extra-long Titanium modular femoral neck component after implantation. Worldwide there were 680 Long and X-Long PROFEMUR Titanium modular neck fractures among 123,840 global sales representing is a cumulative rate of modular neck device fracture of 0.55% from 2002 to 2019. Within the United States there were 349 Long and X-Long PROFEMUR¿ Titanium modular neck fractures among 15,786 United States sales representing a cumulative rate of modular neck device fracture with a fracture rate in the United States of 2.21% from 2002 to 2019. There is an average time of 5.4 years to device fracture after implantation.
Which lots are affected?
All lots/serial numbers
Where was it sold?
worldwide, except China and Japan
What should I do if I have it?
Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.
What does Class I mean?
Class I is the most serious FDA recall category: there is a reasonable probability that using the product will cause serious health consequences or death.
Read the official FDA notice · Source record retrieved 26 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.
Other products in this recall event
1 other product · FDA event 86153| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| CLASS I | Profemur Neck Extra Long Titanium recalled by MicroPort Orthopedics | MicroPort Orthopedics | Other | TN |
More recalls from MicroPort Orthopedics
All 31Other Hip & Knee Implants recalls
All 3,122| Reported | Class | Recall | Company | Reason | Where |
|---|---|---|---|---|---|
| Device | CLASS II | Halyard Anterior Hip Pack recalled by Avid Medical | Avid Medical | Sterility | Nationwide |
| Device | CLASS II | Halyard Anterior Hip Pack recalled by Avid Medical | Avid Medical | Sterility | Nationwide |
| Device | CLASS II | Medline medical convenience kits labeled as: Hip Scope Pack recalled | Medline Industries | Other | Nationwide |
| Device | CLASS II | TS Femoral Prep Tray, Triathlon recalled by Howmedica Osteonics | Howmedica Osteonics | Sterility | NJ |
| Device | CLASS II | Grafton" DBM and Grafton Plus" DBM contain demineralized recalled | Medtronic Sofamor Danek USA | Other Bacterial Contamination | Nationwide |