CLASS III Device recall · Reported 7 Nov 2018 · FDA Enforcement Report

Software Package, iPAW 4.2 User Kit, Part No. B73489 recalled

Beckman Coulter is recalling Software Package, iPAW 4.2 User Kit, Part No. B73489, distributed nationwide in the US. The recall was initiated on 24 May 2018 and the FDA has classified it as Class III.

Check your package

Lot, batch or date codesv4.2.1 (and 4.2, discontinued)
Quantity recalled14

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

Recall details

Recall number
Z-0356-2019
FDA event ID
80434
Recalling firm
Beckman Coulter, Brea, CA
Classification
Class III
Status
Terminated
Recall initiated
24 May 2018
FDA classified
31 Oct 2018
Reported
7 Nov 2018
Type
Voluntary: Firm initiated
Customers notified by
N/A
Reason category
Packaging Defects
Device type
Medical Software

Timeline

24 May 2018Recall initiated by company
31 Oct 2018Classified by FDA+160 days
7 Nov 2018Published in enforcement report+7 days

Companies usually start a recall weeks before the FDA classifies and publishes it; the gap above is that lag.

Reason for recall

Sorting-Drive software version 4.2 (released in October 2015) introduced a new option for iPAW and the Sorting-Drive Client that is used for manual printing of barcodes. When printing consecutively numbered tube labels using this optional Barcode Counter function, the system incorrectly converts numbers with consecutive multiple zeroes in the middle, potentially leading to wrong barcode IDs. The firm reports that this does not affect automated label creation or reprinting of individual labels and that no other system functions are affected.

Packaging recalls include wrong labels, wrong products in the wrong bottle, missing leaflets, short-filled or empty capsules and seals that fail.

Product as listed by the FDA

Software Package, iPAW 4.2 User Kit, Part No. B73489, Manufactured by: Beckman Coulter Biomedical GmbH The iPAW 4.2 User Kit (PN B73489) includes the iPAW software application CD (version 4.2). This function is primarily used to copy an existing barcode ID to replace the label of an individual sample tube because the original label is deteriorated.

Where it was distributed

Worldwide Distribution: US (nationwide) and countries of: Algeria, Argentina, Austria, Belgium, Brazil, Chile, China, Czech Republic, Denmark ,France, Germany, Greece ,Hong Kong, India, Ireland, Israel, Italy ,Republic of Korea, Lebanon, Lithuania ,Malaysia, Netherlands, Poland, Portugal , Qatar, Romania, Russian Federation, Saudi Arabia ,South Africa , Spain, Sweden, Taiwan, Turkey , and United Kingdom.

Nationwide

Questions about this recall

Is Software Package, iPAW 4.2 User Kit, Part No. B73489 recalled?

Yes. Beckman Coulter recalled Software Package, iPAW 4.2 User Kit, Part No. B73489 on 24 May 2018. The recall is Class III and its status is Terminated. Recall number Z-0356-2019.

Why was it recalled?

Sorting-Drive software version 4.2 (released in October 2015) introduced a new option for iPAW and the Sorting-Drive Client that is used for manual printing of barcodes. When printing consecutively numbered tube labels using this optional Barcode Counter function, the system incorrectly converts numbers with consecutive multiple zeroes in the middle, potentially leading to wrong barcode IDs. The firm reports that this does not affect automated label creation or reprinting of individual labels and that no other system functions are affected.

Which lots are affected?

v4.2.1 (and 4.2, discontinued)

Where was it sold?

Worldwide Distribution: US (nationwide) and countries of: Algeria, Argentina, Austria, Belgium, Brazil, Chile, China, Czech Republic, Denmark ,France, Germany, Greece ,Hong Kong, India, Ireland, Israel, Italy ,Republic of Korea, Lebanon, Lithuania ,Malaysia, Netherlands, Poland, Portugal , Qatar, Romania, Russian Federation, Saudi Arabia ,South Africa , Spain, Sweden, Taiwan, Turkey , and United Kingdom.

What should I do if I have it?

Stop using the device if the notice says to, and contact the manufacturer or your healthcare provider for the correction or replacement.

What does Class III mean?

Class III recalls are for products unlikely to cause any adverse health consequence, usually labelling or quality issues.

Read the official FDA notice · Source record retrieved 21 Sep 2026. The FDA describes openFDA data as unvalidated; the official notice takes precedence. This page reports the record and gives no medical advice.

More recalls from Beckman Coulter

All 334

Other Medical Software recalls

All 903